Stackable Energy Storage Connector: 70A Floating and 240A Stationary

PVLinkTech stackable energy storage connectors connect adjacent battery modules in a stack. Choose between a 70A floating model designed to accommodate module misalignment and a 240A stationary model rated at 1500V DC with IP67 protection when properly mated. Compare electrical ratings, panel requirements and mounting drawings to find the right option for your battery system.

Explore Our Products

Floating or Stationary: The Decision Comes First

A floating contact is built with clearance, so the plug can find the receptacle while modules are being stacked. A stationary contact has no such clearance. It holds position, which means the stack itself has to be true before the two halves meet. That one difference decides what a stackable energy storage connector has to be: current rating, voltage class, protection level and panel thickness.

70A floating stackable energy storage connector
70A Floating Connector
240A stationary stackable energy storage connector
240A Stationary Connector
Specifications comparison of 70A floating and 240A stationary energy storage connectors.
Parameter70A floating240A stationary
Rated current50A–70A120A–240A
Rated voltage / dielectric strength220V DC / 500V AC1500V DC / 4000V AC
Stack-up errorAbsorbs misalignment between modulesHolds position; the stack must carry the alignment
Housing / contactsPA66 / gold-plated brassPA66 / T2Y copper, silver plated
Mounting screwM4M4
Ingress protectionNone rated; UL94 V-0 flame rating onlyIP67
Panel thickness3.0 mm, ±0.05 mm tolerance2–3 mm recommended
Contact resistance≤0.5 mΩ≤0.5 mΩ
Insulation resistance>10MΩ @ 500V DC>10MΩ @ 500V DC
Operating temperature-40°C to +125°C-40°C to +125°C

Swipe left or right to compare specifications.

70A Floating Stackable Connector: What the Clearance Buys You

The 70A stackable energy storage connector exists for one reason: modules rarely line up exactly, and a stack of eight or twelve of them compounds that. Clearance in the contact lets the plug settle into the receptacle as the module slides home, so the assembly does not have to be forced straight. That is the whole value, and it is why the 70A part carries the lower voltage class. It is a pack-internal connection at 220V DC, not a cabinet feed.

Gold plating on the brass contacts keeps the mating surface stable across the service life of the pack, which matters more in a residential unit that may sit closed for a decade than in a cabinet that gets serviced. Both halves are supplied as a matched pair: the receptacle mounts to one module, the plug to the next.

70A floating stackable connector plug-side mounting drawing
Plug-Side Mounting Drawing
70A floating stackable connector socket-side mounting drawing
Socket-Side Mounting Drawing

240A Stationary Stackable Connector: Where the Current Goes

The 240A stackable energy storage connector holds a fixed center distance instead of absorbing error. In exchange it carries 120A–240A at 1500V DC, which is the class where a commercial pack or a cabinet feed actually operates. Contacts are T2Y copper with silver plating, the same conductor material used in the CN series, and the housing is PA66 with a UL94 V-0 rating behind IP67 when mated.

Where Stack-Up Error Comes From

A stack is a chain of tolerances. Each module brings a panel thickness within its own limit, a hole position within its own limit, and a little tilt from the rails. The joint at the far end of the stack sees the sum. With a stationary contact, that sum has to be smaller than the clearance inside the connector, so the stackable energy storage connector only works if the stack is designed and built to hold it. With a floating contact, the connector spends its clearance on the sum, and the stack can be built to ordinary sheet metal tolerance.

Six Checks Before You Specify a Stackable Connector

Six checks decide which stackable energy storage connector goes into a stack, and the first four are usually enough.

  1. Current at the module joint. Up to 70A takes the floating version. A 120A–240A joint takes the stationary version.
  2. Voltage class. 220V DC and 1500V DC do not belong on the same stack. Match the connector to the string, end to end.
  3. Panel thickness. The floating version is drawn for 3.0 mm. The stationary version takes 2–3 mm.
  4. Contact layout. Send the drawing with the contact count and spacing you need. We confirm the layout against that drawing before tooling.
  5. Protection. IP67 is available on the stationary version only. If the joint is exposed, that decides the model for you.
  6. Mounting hardware. M4 on both versions, so the screw callout does not separate them. Do not read the shared screw size as interchangeability.

What to Send for a Quote

A stackable energy storage connector quote moves faster with six pieces of information: number of modules in the stack, the stack or panel drawing, working current at the joint, system voltage, panel thickness, and cable size per module. Add the quantity and the date you need the first batch. If the drawing is not final, send the current revision anyway and mark what is still open. We would rather quote against a draft than guess at a hole pattern.

Get a stackable energy storage connector quote for your module layout

Send the drawing, the module count and the current at the joint. We will come back with the model, the panel cutout check and a sample date.

Request a sample

or read how ordering works before you send the drawing.

FAQ

Do both versions carry the same protection rating?

No. The 240A stationary connector is IP67 when mated, with a UL94 V-0 housing. The 70A floating connector carries the UL94 V-0 flame rating only, with no IP code. That reflects where each part is used: inside a sealed pack, or on a panel that can be exposed.

Can I use the 70A floating connector on a 120A module?

No. Its rated current is 50A–70A. Above that, the stationary version of the stackable energy storage connector covers 120A–240A at 1500V DC.

Are these the same connectors as the CN series?

No, and they are not interchangeable. The CN series is a cable connector that terminates a conductor; the stackable range is a panel-mounted pair that joins modules. If your joint is a cable to a rack or cabinet, start with the energy storage connectors page instead.

What screws do they take?

M4 on both versions. The 70A part is drawn with a 3.0 mm panel and a ±0.05 mm tolerance. The 240A part recommends a 2–3 mm panel.

Do I get the plug and the receptacle together?

Yes. Both halves are supplied as a matched pair, since the clearance and the contact alignment are properties of the pair rather than of one half.

Where do I start if I have never specified one of these?

Send the stack drawing and the module count. If the stack is already built, tell us what misalignment you are seeing at the last joint. That single number usually settles floating versus stationary faster than a spec sheet.

LET’S BUILD YOUR CONNECTION SOLUTION

GET THE RIGHT CONNECTOR FOR YOUR PROJECT

Share your application, specifications, and estimated quantity. Our team will recommend a suitable connector solution and provide a quotation.

Low MOQ · OEM & ODM · Product Selection Support · Fast Quote Response

DOWNLOAD 2026 CATALOG